What Should the Operator Do When the Safety Relay of the Styrofoam Compactor Fails?

Thanks to the advantages of a high compression ratio of 90:1 and zero pollution, the Styrofoam compactor is now the first choice for many recyclers to recycle Styrofoam. Styrofoam compactor has been invested in recycling by THE BRICK, GREEN, RAGN SELL, and other companies. It has covered all walks of life that need to recycle Styrofoam.

Safety relay is a common part of machinery, which protects different levels of machinery. The main goal is to protect the mechanical operators exposed to different levels of danger. It plays the same role in the Styrofoam compactor. But every part of the machine has a certain possibility of failure, how should the operator remove the cause of the failure and solve it?

Fault phenomenon: the equipment cannot be started, and the working indicator light is not on.

Possible causes: abnormal voltage input or no voltage input.

Treatment: first check whether the voltage of the 24V output power supply is normal, and then check whether the coil voltage is 24V.

Fault phenomenon: the relay cannot be reset.

Possible cause 1: abnormal voltage input or no voltage input.

Treatment 1: check whether the emergency stop button is in the pull-out state

Possible cause 2: The contactor is working

Treatment 2: check whether all contactor coils are in power loss state (that is, all contactors are in non-working state)

In fact, thanks to Styrofoam compactor is favored by many recyclers, many professional recycling companies, such as GREENMAX Recycling, will be equipped with complete instructions, which can guide the operators to deal with the above-mentioned faults calmly. So, please don’t panic when you encounter relevant problems.